Known Issues
Tracking of known problems, workarounds and fix status across versions.
Active Issues
No known active issues on the latest version (26.03).
Resolved Issues
| Issue | Affected Versions | Fixed in | Workaround |
|---|---|---|---|
| .NET 8 install triggers data corruption on ARM architectures | 25.02 | 25.03 | No workaround available |
| DOMService synchronization sometimes stuck | 24.07 | 24.10 | In DOMPloy 12.0: click the Offline tab |
| Online coupling stuck in "coupling" state | 22.12 | 23.03 | Open RFNM settings → "route devices" tab → submit again |
| Battery replacement not always detected | 23.07 | 23.10 | No workaround available |
Third-Party Issues Handled
DOMController proactively works around known issues in third-party components it depends on.
| Issue | Component | Handled since |
|---|---|---|
| Backup file corruption on affected MariaDB versions (10.5.25, 10.6.18, 10.11.8, 11.0.6, 11.1.5, 11.2.4, 11.4.2) | MariaDB | 25.04 |
Issue Details
.NET 8 install triggers data corruption on ARM architectures
FIXED
Affected versions: 25.02
Fixed in: 25.03
Description: Installing .NET 8 on the standard (ARM) DOMController triggers data corruption in the services.
Workaround: No workaround available. Upgrading to version 25.03, which completes the migration to .NET 8, is recommended.
DOMService synchronization sometimes stuck
FIXED
Affected versions: 24.07
Fixed in: 24.10
Description: Synchronization with the DOMService application could randomly get stuck.
Workaround: A workaround is available in DOMPloy 12.0 by clicking on the "Offline" tab.
Online coupling stuck in "coupling" state
FIXED
Affected versions: 22.12
Fixed in: 23.03
Description: Online coupling could sometimes get stuck indefinitely with the device remaining in "coupling" state.
Workaround: Open RFNM settings → go to the "route devices" tab → submit the configuration again.
Battery replacement not always detected
FIXED
Affected versions: 23.07
Fixed in: 23.10
Description: Battery replacement was not always correctly detected and stored.
Workaround: No workaround available. Upgrading to version 23.10 is recommended.